ChemiDoc |
BioRad ChemiDoc XRS |
BioRad ChemiDoc XRS molecular imager, chemiluminescence, fluorescence, colorimetric detection, HQ2 CCD Camera.
Primarily used for molecular imaging of diverse biological assays.
Quantity One software |
|
|
|
Circular Dichroism Spectrophotometer (CD) |
Jasco J-1500 |
Jasco J-1500 circular dichroism spectrophotometer (CD), 1cm path length, Peltier sample temperature control, fluorescence accessories.
Primarily used for secondary structure determination of proteins.
Spectra Manager software |
|
|
|
Differential Scanning Calorimeter (DSC) |
Netzsch 214 Polyma |
Netzsch 214 Polyma DSC (differential scanning calorimeter), -40°C to 600°C, requires Concavus pans/lids. TGA of your material must be run before you can use this instrument.
Primarily used for quantitative characterization of diverse solids.
Proteus 80 software |
|
|
|
Flow Cytometer (FACS) |
BectonDickinson Accuri C6 |
BectonDickinson Accuri C6+ flow cytometer, dual lasers (488nm blue and 640nm red), dual light scatter detectors (forward 0° ± 13° and side 90° ± 13°), four channel emission detection (533/30nm, 585/40nm, >670nm, 675/25nm), 200mm ID flow cell.
Primarily used for analysis of cellular processes and… |
|
|
|
Fluorescence Spectrometer |
Hitachi F-4500 |
Hitachi F-4500 Fluorescence spectrophotometer, R298 photomultiplier, 200-900nm, 1cm cuvette (four polished windows).
Primarily used for diverse bioanalytical assays.
FL Solutions software |
|
|
|
Fourier Transform Infrared Spectrometer (FT-IR) |
Bruker Optics Vertex 70 |
Bruker Optics Vertex 70 FT-IR, Specac Golden Gate ATR and various sampling accessories,
Primarily used to acquire mid-IR spectra (~4000cm-1 to ~750cm-1) of solids and solutions.
OPUS software |
|
|
|
Gas Chromotography - Mass Spectrometer (GC-MS) |
Agilent 7890B GC |
Agilent 7890B GC, Agilent DB-5ms Ultra Inert column (30m x 0.25mm x 0.25mm), ~45°C to 325°C, Agilent 7693 autosampler with 150 sample tray, and Agilent 5977A single quadrupole MSD (Extractor EI source, triple-axis detector, turbo pump), unit resolution m/z.
Primarily used to separate, quantitate, and… |
|
|
|
Graphite Furnace Atomic Absorption Spectrometer (GF-AAS) |
Perkin Elmer PinAAcle 900z |
Perkin Elmer PinAAcle 900z graphite furnace atomic absorption spectrometer (GF-AAS), longitudinal Zeeman furnace, dual beam, AS 900 Autosampler (148 vessel positions).
Primarily used for quantitative single-element microanalysis of aqueous solutions at ppt working concentrations. Available hollow cathode lamps include Cu… |
Pricing determined by project needs
|
|
|
Inductively Coupled Plasma Optical Emisssion Spectrometer (ICP-OES) |
Perkin Elmer Optima 8000 CROSS FLOW |
Perkin Elmer Optima 8000 CROSS FLOW inductively coupled plasma optical emission spectrometer (ICP-OES), Scott spray chamber, cross flow nebulizer, flat plate plasma, CCD array detector, axial and radial acquisition modes, S10 autosampler (157 vessel positions).
Primarily used for quantitative multi-element… |
Pricing determined by project needs
|
|
|
Liquid Chromotography - Mass Spectrometer (LC-MS) |
Analytical-scale Agilent 1200 HPLC stack |
Analytical-scale Agilent 1200 HPLC stack (400bar max, degasser, bin pump, HiP ALS -108 sample capacity, TCC, DAD w/10uL flow cell), two ES Industries Epic C-18 MSO columns (50x2.1mm 2.3mm 150Å), acidic (formic acid/acetonitrile) and basic (ammonium acetate/acetonitrile) gradient chromatography conditions, Agilent 6130A single quadrupole MSD (… |
|
|
|
Lyophilizer |
SP Scientific VirTis BenchTop Pro ZL |
SP Scientific VirTis BenchTop Pro ZL lyophilizer, Omnitronics controller, 12 port tree-type stainless steel manifold, -105°C 8L condenser, ~50mT vacuum.
Primarily used to freeze dry diverse materials. |
|
|
|
Microvolume and Cuvette Spectrophotometer |
Thermo Scientific NanoDrop 2000c |
Thermo Scientific NanoDrop 2000c microvolume and cuvette spectrophotometer, 1-2mL (microvolume) or 1cm cuvette, 190-840nm. Bacteria/yeast/cells prohibited. Not for cell growth analysis (colorimetric or densitometry).
Primarily used for protein/peptide analysis.
… |
|
|
|
Nuclear Magnetic Resosonance (NMR) |
500MHz 3-channel Bruker Avance Neo |
500MHz 3-channel Bruker Avance Neo with Prodigy BBO cryoprobe, SampleExpress (60 sample), automatic tuning/matching, ambient to 50°C sample temperature, non-uniform sampling for 2D experiments. Most NMR-active nuclei are observable including commonly used: 1H, 2H, 11B, 13C, 15N, 19F, 29Si, 31P, 35Cl.
Primarily used… |
|
|